The Sentry Safety 4200FR Series Panic Exit Bar is a 3-hour fire-rated, UL Listed dual-door panic exit device designed to provide reliable emergency egress for commercial fire-rated openings. Built to meet ANSI/BHMA Grade 1 standards, this stainless steel vertical rod panic bar offers dependable performance in high-traffic environments while meeting strict safety and durability requirements. The surface-mounted design includes vertical rods, a steel strike for the door frame, and a universal configuration that allows installation on either right- or left-handed doors.
Designed specifically for dual-door applications, the 4200FR Series allows openings without a center mullion to function as secure emergency exits. It is ideal for schools, hospitals, warehouses, industrial facilities, and other commercial buildings requiring fire-rated exit hardware. Available in painted or stainless steel finishes, this panic bar combines long-lasting durability with reliable operation for demanding applications.
Recommended Applications:
- Fire-rated doors designed to help prevent the spread of fire and smoke between areas
- Fire-rated glass doors with a minimum 1-1/2" metal stile
- Steel, wood, and composite solid-face doors
- Doors with a minimum width of 25"
- Doors requiring UL Listed and 3-hour fire-rated exit hardware
- Dual doors without mullions requiring a vertical rod panic exit solution
- Dual-door applications where a 4000FR Series Panic Exit Bar is used on the paired door
- High-traffic commercial buildings such as schools, hospitals, warehouses, industrial facilities, and public buildings
Not Recommended For:
- Non-fire-rated doors
- Doors held locked by magnetic locks, as this panic bar cannot release a magnetic lock
- Applications where a non-fire-rated panic device is required
- Door openings that do not meet the required size or fire-rating specifications
- Applications requiring dogging, as fire-rated versions do not include a dogging feature
Panic Exit Pro offers more expert access control assistance than anyone.
We have carefully selected entry control devices for every scenario, allowing you to put together a kit that is not only cost-effective but also includes all the components you need - no more, no less. Don't overspend on a system with controls you won't use or compromise functionality by leaving out components you need because they aren't included in other retailers' pre-designed kits. If you need help deciding whether this access control device is part of the right solution for your business, our live application specialists are available from 9 AM to 9 PM EST, 7 days a week. You can also send us an email 24/7, and we'll be happy to assist you. |
- UL Listed and approved
- 3-hour fire-rated for use on fire doors
- ANSI/BHMA Grade 1 certified for superior durability
- Designed for dual-door applications with vertical rods
- Rim type, surface-mounted installation
- Universal handing for right- or left-handed doors
- Includes steel strike for the door frame
- Available in painted or stainless steel finishes
- Fire-rated device does not include dogging
Panic Exit Pro makes a pro of the small business owner.
We specialize in DIY installation because we know that, as a small business owner, every penny saved helps. We have developed customized instructions, videos, and offer a full range of accessories to cover every aspect of your entry system installation. In addition, we have the largest staff of factory-trained technicians in the U.S. |
| Product |
Specifications |
| Product Type |
Fire-Rated Vertical Rod Panic Exit Bar |
| Series |
4200FR Series |
| Fire Rating |
3 Hours |
| Listing |
UL Listed |
| ANSI/BHMA Grade |
Grade 1 |
| Mounting Style |
Surface Mount |
| Latch Type |
Vertical Rod Two-Point Latch |
| Door Application |
Dual Doors |
| Bar Length |
40 in. |
| Handing |
Universal (Right or Left Hand) |
| Door Types |
Fire-rated wood, steel, composite, and glass doors with minimum 1-1/2 in. stile |
| Finish Options |
Painted or Stainless Steel |
- Sentry Safety 4200FR Series Panic Exit Bar
- Vertical Rod Assembly
- Steel Door Frame Strike
- Installation Instructions
Panic Exit Pro has the resources you need.
How do you use your entry system once you have it? Panic Exit Pro is the only retailer that provides a real answer to this question. We have developed videos to help you understand many of our door entry components and products, and we write DIY-focused manuals for most entry system accessories. |
Fire Rated:
The Sentry Safety 4200FR Panic Exit Bar has passed a 3-hour fire resistance test to ensure reliable performance in a variety of situations. The 4200FR Series also meets ANSI/BHMA Grade 1 standards for panic exit hardware. This means the device meets strict criteria for performance characteristics, physical properties, test values, and safety requirements. Product grades are defined by ANSI/BHMA standards, with Grade 1 being the highest. Not only does this series meet high safety standards, but it also meets the highest quality standards, ensuring reliable operation time after time.
Trimming the Panic Bar to Size:
The bar comes with a total length of 40". It does not have to span the entire width of the door, provided the door has a flat mounting surface, so it can be used on doors wider than 40". If the bar needs to be shortened, the process is simple. The portion of the panic exit bar beyond the alarm key is hollow tubing. Simply cut the tubing to the desired length and install the included end cap. This panic bar can be trimmed down to 30".
Changing from Right or Left Hand Mounting:
To change the handing, remove the top section of the bar by removing the four screws. Unscrew the flathead screw located below the spring to disengage the top piece from the panic bar. Loosen the screw that the spring is attached to and remove the spring. Attach the spring to the opposite screw, tighten it, and secure it in the opposite hole. Reinstall the flathead screw on the opposite side to reattach the top piece to the panic bar.
Latching and Mounting:
This panic bar is surface mounted and is installed on the rear face of the door. The strike mounts on the door frame behind the door, not on the inside of the frame where a handle may have previously been installed. If the door has an existing handle, it will need to be removed. Caps are available to cover the hole left behind after the handle is removed. Door jamb brackets are also available to cover where the old handle latched to the frame. Mounting bolts are provided; however, depending on the door material, you may choose to use wood screws, self-tapping metal screws, or, for added strength, sex bolts. Sex bolts have a female side on the outside of the door and a male side on the inside that join together through the door. Since both faces of the door are used to secure the bar, they provide a very strong installation.
Optional Accessories (Sold Separately):
4000FR Series Panic Exit Bar
The 4200FR Series panic bar can be used in conjunction with the 4000FR Series panic bar on dual-door applications. The 4200FR Series top and bottom latches secure one door to the frame, while the 4000FR Series bar secures the second door to the first door. This configuration is ideal for overlapping double doors. If your dual doors overlap, using a 4200FR Series Panic Exit Bar with a 4000FR Series Panic Exit Bar allows both doors to open when the 4200FR Series push bar is pressed.
Outside Door Handle With Key Release
If you need access from the outside, you must purchase this accessory; otherwise, the door can only be opened from the inside using the panic bar. The handle is key-lockable. The key provides a non-momentary release. If you unlock the handle from the outside, you must relock it to secure the door again. Unlike some keyed handles, this one is not spring-loaded and does not automatically return to the locked position. The key does not disengage the panic bar directly. Instead, it engages or disengages the handle, which then releases the panic bar. The keyed lever handle is also available in a keyed-alike option. Please note that if the alarm is active, operating the lever handle will trigger the alarm.
Panic Exit Pro has actual experience.
We have a dedicated testing area, provide factory and in-house training, have installed this equipment on our own properties, attend industry trade shows in multiple countries, and visit our manufacturers' factories. When you see and use as many products as we have, you develop ideas for small improvements that make a significant difference. We have put those ideas into practice and used them to help thousands of customers create entry control solutions that work for their unique applications. |